| Improper verification of cryptographic signature in Windows Admin Center allows an authorized attacker to elevate privileges locally. |
| Missing authentication for critical function in SQL Server allows an authorized attacker to elevate privileges over a network. |
| Improper access control in Windows Deployment Services allows an unauthorized attacker to execute code over an adjacent network. |
| Windows Secure Boot stores Microsoft certificates in the UEFI KEK and DB. These original certificates are approaching expiration, and devices containing affected certificate versions must update them to maintain Secure Boot functionality and avoid compromising security by losing security fixes related to Windows boot manager or Secure Boot.
The operating system’s certificate update protection mechanism relies on firmware components that might contain defects, which can cause certificate trust updates to fail or behave unpredictably. This leads to potential disruption of the Secure Boot trust chain and requires careful validation and deployment to restore intended security guarantees.
Certificate Authority (CA)
Location
Purpose
Expiration Date
Microsoft Corporation KEK CA 2011
KEK
Signs updates to the DB and DBX
06/24/2026
Microsoft Corporation UEFI CA 2011
DB
Signs 3rd party boot loaders, Option ROMs, etc.
06/27/2026
Microsoft Windows Production PCA 2011
DB
Signs the Windows Boot Manager
10/19/2026
For more information see this CVE and Windows Secure Boot certificate expiration and CA updates. |
| Use of uninitialized resource in Dynamic Root of Trust for Measurement (DRTM) allows an authorized attacker to disclose information locally. |
| Improper Control of Filename for Include/Require Statement in PHP Program ('PHP Remote File Inclusion') vulnerability in omnipressteam Omnipress omnipress allows PHP Local File Inclusion.This issue affects Omnipress: from n/a through <= 1.6.6. |
| Missing Authorization vulnerability in webdevstudios Automatic Featured Images from Videos automatic-featured-images-from-videos allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects Automatic Featured Images from Videos: from n/a through <= 1.2.7. |
| Early versions of Operator-SDK provided an insecure method to allow operator containers to run in environments that used a random UID. Operator-SDK before 0.15.2 provided a script, user_setup, which modifies the permissions of the /etc/passwd file to 664 during build time. Developers who used Operator-SDK before 0.15.2 to scaffold their operator may still be impacted by this if the insecure user_setup script is still being used to build new container images.
In affected images, the /etc/passwd file is created during build time with group-writable permissions and a group ownership of root (gid=0). An attacker who can execute commands within an affected container, even as a non-root user, may be able to leverage their membership in the root group to modify the /etc/passwd file. This could allow the attacker to add a new user with any arbitrary UID, including UID 0, leading to full root privileges within the container. |
| Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) allow account passwords to be changed through the maintenance interface without requiring verification of the existing password. This enables unauthorized password changes when access to the affected endpoint is obtained. |
| Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) ship with a predefined default password for a built-in authentication account that is not required to be changed during initial configuration. An attacker can leverage these default credentials to gain authenticated access to the management interface. |
| A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service. |
| A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption. |
| Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) disclose sensitive account credentials in cleartext within HTTP responses generated by the maintenance interface. Because the management interface is accessible over unencrypted HTTP by default, credentials may be exposed to network-based interception. |
| A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop. |
| A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user. |
| A Missing Authorization vulnerability in Juniper Networks Security Director allows an unauthenticated network-based attacker to read or tamper with multiple sensitive resources via the web interface.
Numerous endpoints on the Juniper Security Director appliance do not validate authorization and will deliver information to the caller that is outside their authorization level. An attacker can access data that is outside the user's authorization level. The information obtained can be used to gain access to additional information or perpetrate other attacks, impacting downstream managed devices.
This issue affects Security Director version 24.4.1. |
| An Out-of-bounds Write vulnerability in the connectivity fault management (CFM) daemon of Juniper Networks Junos OS on MX Series with MPC-BUILTIN, MPC1 through MPC9 line cards allows an unauthenticated adjacent attacker to send a malformed packet to the device, leading to an FPC crash and restart, resulting in a Denial of Service (DoS).
Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition.
This issue affects Juniper Networks:
Junos OS:
* All versions before 22.2R3-S1,
* from 22.4 before 22.4R2.
This feature is not enabled by default. |
| A Missing Authentication for Critical Function vulnerability in Juniper Networks Security Director Policy Enforcer allows an unauthenticated, network-based attacker to replace legitimate vSRX images with malicious ones.
If a trusted user initiates deployment, Security Director Policy Enforcer will deliver the attacker's uploaded image to VMware NSX instead of a legitimate one.
This issue affects Security Director Policy Enforcer:
* All versions before 23.1R1 Hotpatch v3.
This issue does not affect Junos Space Security Director Insights. |
| An Improper Check for Unusual or Exceptional Conditions vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated, network-based attacker to cause an integrity impact to the downstream devices.
When a peer sends a BGP update message which contains the aggregator attribute with an ASN value of zero (0), rpd accepts and propagates this attribute, which can cause issues for downstream BGP peers receiving this.
This issue affects:
Junos OS:
* All versions before 21.4R3-S6,
* 22.2 versions before 22.2R3-S3,
* 22.4 versions before 22.4R3;
Junos OS Evolved:
* All versions before 21.4R3-S7-EVO,
* 22.2 versions before 22.2R3-S4-EVO,
* 22.4 versions before 22.4R3-EVO. |
| A Deadlock vulnerability in the packet forwarding engine (PFE) of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service (DoS).
When a large amount of traffic is processed by ATP Cloud inspection, a deadlock can occur which will result in a PFE crash and restart. Whether the crash occurs, depends on system internal timing that is outside the attackers control.
This issue affects Junos OS on SRX Series:
* All versions before 21.3R3-S1,
* 21.4 versions before 21.4R3,
* 22.1 versions before 22.1R2,
* 22.2 versions before 22.2R1-S2, 22.2R2. |