| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| IBM dashDB Local uses hard-coded credentials that could allow a remote attacker to gain access to the Docker container or database. |
| An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application uses a hard-coded username with no password allowing an attacker into the system without authentication. |
| An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded private cryptographic keys that may allow an attacker to decrypt traffic from any other source. |
| Mutiny 7.2.0-10788 suffers from Hardcoded root password. |
| Common encryption key appears to be used across all deployed instances of Serv-U FTP Server. Because of this an encrypted value that is exposed to an attacker can be simply recovered to plaintext. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Nokia Fastmile 3tg00118abad52 devices shipped by Optus are shipped with a default hardcoded admin account of admin:Nq+L5st7o This account can be used locally to access the web admin interface. |
| GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks. |
| Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. |
| Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software. |
| The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions. |
| Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |
| Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module. |
| An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings. |