| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Linear eMerge E3-Series devices have Cleartext Credentials in a Database. |
| SmarterTools SmarterMail 16.x before build 6985 allows deserialization of untrusted data. An unauthenticated attacker could run commands on the server when port 17001 was remotely accessible. This port is not accessible remotely by default after applying the Build 6985 patch. |
| This improper link resolution vulnerability allows remote attackers to access system files. To fix this vulnerability, QNAP recommend updating QTS to their latest versions. |
| ColdFusion versions Update 1 and earlier, Update 7 and earlier, and Update 15 and earlier have a deserialization of untrusted data vulnerability. Successful exploitation could lead to arbitrary code execution. |
| Synacor Zimbra Collaboration Suite 8.7.x through 8.8.11 allows insecure object deserialization in the IMAP component. |
| A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol. |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneider Electric Software Update (SESU) SUT Service component (V2.1.1 to V2.3.0) |
| An information exposure vulnerability in the external authentication profile form of FortiSIEM 5.2.2 and earlier may allow an authenticated attacker to retrieve the external authentication password via the HTML source code. |
| On BIG-IP versions 15.0.0-15.0.1, 14.1.0.2-14.1.2.2, 14.0.0.5-14.0.1, 13.1.1.5-13.1.3.1, 12.1.4.1-12.1.5, 11.6.4-11.6.5, and 11.5.9-11.5.10, the access controls implemented by scp.whitelist and scp.blacklist are not properly enforced for paths that are symlinks. This allows authenticated users with SCP access to overwrite certain configuration files that would otherwise be restricted. |
| On BIG-IP 13.1.0-13.1.1.4, sensitive information is logged into the local log files and/or remote logging targets when restjavad processes an invalid request. Users with access to the log files would be able to view that data. |
| BIG-IP APM Edge Client before version 7.1.8 (7180.2019.508.705) logs the full apm session ID in the log files. Vulnerable versions of the client are bundled with BIG-IP APM versions 15.0.0-15.0.1, 14,1.0-14.1.0.6, 14.0.0-14.0.0.4, 13.0.0-13.1.1.5, 12.1.0-12.1.5, and 11.5.1-11.6.5. In BIG-IP APM 13.1.0 and later, the APM Clients components can be updated independently from BIG-IP software. Client version 7.1.8 (7180.2019.508.705) and later has the fix. |
| On version 1.9.0, If DEBUG logging is enable, F5 Container Ingress Service (CIS) for Kubernetes and Red Hat OpenShift (k8s-bigip-ctlr) log files may contain BIG-IP secrets such as SSL Private Keys and Private key Passphrases as provided as inputs by an AS3 Declaration. |
| Platform dependent weakness. This issue only impacts iSeries platforms. On these platforms, in BIG-IP (LTM, AAM, AFM, Analytics, APM, ASM, DNS, Edge Gateway, FPS, GTM, Link Controller, PEM, WebAccelerator) versions 14.0.0-14.1.0.1, 13.0.0-13.1.1.3, and 12.1.1 HF2-12.1.4, the secureKeyCapable attribute was not set which causes secure vault to not use the F5 hardware support to store the unit key. Instead the unit key is stored in plaintext on disk as would be the case for Z100 systems. Additionally this causes the unit key to be stored in UCS files taken on these platforms. |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords. |
| In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak. |
| An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP. |
| An attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) if the attacker is in an MITM position. |
| AVEVA Wonderware System Platform 2017 Update 2 and prior uses an ArchestrA network user account for authentication of system processes and inter-node communications. A user with low privileges could make use of an API to obtain the credentials for this account. |
| There is a deserialization vulnerability in Chatopera cosin v3.10.0. An attacker can execute commands during server-side deserialization by uploading maliciously constructed files. This is related to the TemplateController.java impsave method and the MainUtils toObject method. |
| Kyocera Command Center RX TASKalfa4501i and TASKalfa5052ci allows remote attackers to abuse the Test button in the machine address book to obtain a cleartext FTP or SMB password. |