CVE-2025-43006 2025-05-13 6.1 Medium
SAP Supplier Relationship Management (Master Data Management Catalogue) allows an unauthenticated attacker to execute malicious scripts in the application, potentially leading to a Cross-Site Scripting (XSS) vulnerability. This has no impact on the availability of the application, but it can have some minor impact on its confidentiality and integrity.
CVE-2025-43004 2025-05-13 5.3 Medium
Due to a security misconfiguration vulnerability, customers can develop Production Operator Dashboards (PODs) that enable outside users to access customer data when they access these dashboards. Since no mechanisms exist to enforce authentication, malicious unauthenticated users can view non-sensitive customer information. However, this does not affect data integrity or availability.
CVE-2025-43002 2025-05-13 4.3 Medium
SAP S4CORE OData meta-data property allows an authenticated attacker to access restricted information due to missing authorization check. This could cause a low impact on confidentiality but integrity and availability of the application are not impacted.
CVE-2025-41645 2025-05-13 8.6 High
An unauthenticated remote attacker could use a demo account of the portal to hijack devices that were created in that account by mistake.
CVE-2025-40628 2025-05-13 N/A
SQL injection vulnerability in DomainsPRO 1.2. This vulnerability could allow an attacker to retrieve, create, update and delete databases via the “d” parameter in the “/article.php” endpoint.
CVE-2025-40556 2025-05-13 6.5 Medium
A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation.
CVE-2025-40555 2025-05-13 4.7 Medium
A vulnerability has been identified in APOGEE PXC+TALON TC Series (BACnet) (All versions). Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted device, and potentially reduce the availability of BACnet network. A power cycle is required to restore the device's normal operation.
CVE-2025-3916 2025-05-13 N/A
CWE-121: Stack-based Buffer Overflow vulnerability exists that could cause local attackers being able to exploit these issues to potentially execute arbitrary code while the end user opens a malicious project file (SSD file) provided by the attacker.
CVE-2025-33025 2025-05-13 9.9 Critical
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'traceroute' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2025-33024 2025-05-13 9.9 Critical
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'tcpdump' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
CVE-2025-31930 2025-05-13 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-24008 2025-05-13 6.5 Medium
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive information, including obfuscated safety passwords.
CVE-2025-24009 2025-05-13 5.9 Medium
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not require authentication to access critical resources. An attacker with network access could retrieve sensitive information from certain data records, including obfuscated safety passwords.
CVE-2025-4396 2025-05-13 7.5 High
The Relevanssi – A Better Search plugin for WordPress is vulnerable to time-based SQL Injection via the cats and tags query parameters in all versions up to, and including, 4.24.4 (Free) and <= 2.27.4 (Premium) due to insufficient escaping on the user supplied parameter and lack of sufficient preparation on the existing SQL query. This makes it possible for unauthenticated attackers to append additional SQL queries to already existing queries that can be used to extract sensitive information from the database.
CVE-2024-57451 1 1000mz 1 Chestnutcms 2025-05-13 7.5 High
ChestnutCMS <=1.5.0 has a directory traversal vulnerability in contentcore.controller.FileController#getFileList, which allows attackers to view any directory.
CVE-2024-21090 1 Oracle 2 Mysql Connector\/python, Mysql Connectors 2025-05-13 7.5 High
Vulnerability in the MySQL Connectors product of Oracle MySQL (component: Connector/Python). Supported versions that are affected are 8.3.0 and prior. Easily exploitable vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise MySQL Connectors. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of MySQL Connectors. CVSS 3.1 Base Score 7.5 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
CVE-2025-24899 1 Yogeshojha 1 Rengine 2025-05-13 7.5 High
reNgine is an automated reconnaissance framework for web applications. A vulnerability was discovered in reNgine, where **an insider attacker with any role** (such as Auditor, Penetration Tester, or Sys Admin) **can extract sensitive information from other reNgine users.** After running a scan and obtaining vulnerabilities from a target, the attacker can retrieve details such as `username`, `password`, `email`, `role`, `first name`, `last name`, `status`, and `activity information` by making a GET request to `/api/listVulnerability/`. This issue has been addressed in version 2.2.0 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2025-24962 1 Yogeshojha 1 Rengine 2025-05-13 8.8 High
reNgine is an automated reconnaissance framework for web applications. In affected versions a user can inject commands via the nmap_cmd parameters. This issue has been addressed in commit `c28e5c8d` and is expected in the next versioned release. Users are advised to filter user input and monitor the project for a new release.
CVE-2025-4304 1 Phpgurukul 1 Cyber Cafe Management System 2025-05-13 7.3 High
A vulnerability, which was classified as critical, was found in PHPGurukul Cyber Cafe Management System 1.0. This affects an unknown part of the file /adminprofile.php. The manipulation of the argument mobilenumber leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.
CVE-2025-4306 1 Phpgurukul 1 Nipah Virus Testing Management System 2025-05-13 7.3 High
A vulnerability was found in PHPGurukul Nipah Virus Testing Management System 1.0 and classified as critical. This issue affects some unknown processing of the file /edit-phlebotomist.php. The manipulation of the argument mobilenumber leads to sql injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.