| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| When the BIG-IP APM 14.1.0-14.1.2, 14.0.0-14.0.1, 13.1.0-13.1.3.1, 12.1.0-12.1.4.1, or 11.5.1-11.6.5 system processes certain requests, the APD/APMD daemon may consume excessive resources. |
| On BIG-IP 14.1.0-14.1.2, 14.0.0-14.0.1, and 13.1.0-13.1.1, undisclosed HTTP requests may consume excessive amounts of systems resources which may lead to a denial of service. |
| On version 14.0.0-14.1.0.1, BIG-IP virtual servers with TLSv1.3 enabled may experience a denial of service due to undisclosed incoming messages. |
| BIG-IP APM Edge Client before version 7.1.8 (7180.2019.508.705) logs the full apm session ID in the log files. Vulnerable versions of the client are bundled with BIG-IP APM versions 15.0.0-15.0.1, 14,1.0-14.1.0.6, 14.0.0-14.0.0.4, 13.0.0-13.1.1.5, 12.1.0-12.1.5, and 11.5.1-11.6.5. In BIG-IP APM 13.1.0 and later, the APM Clients components can be updated independently from BIG-IP software. Client version 7.1.8 (7180.2019.508.705) and later has the fix. |
| On BIG-IP 14.0.0-14.1.0.5, 13.0.0-13.1.2, 12.1.0-12.1.4.1, 11.5.2-11.6.4, FTP traffic passing through a Virtual Server with both an active FTP profile associated and connection mirroring configured may lead to a TMM crash causing the configured HA action to be taken. |
| On versions 14.1.0-14.1.0.5, 14.0.0-14.0.0.4, 13.0.0-13.1.2, 12.1.0-12.1.4.1, and 11.5.2-11.6.4, an attacker sending specifically crafted DHCPv6 requests through a BIG-IP virtual server configured with a DHCPv6 profile may be able to cause the TMM process to produce a core file. |
| In BIG-IP 15.0.0, 14.0.0-14.1.0.5, 13.0.0-13.1.1.5, 12.1.0-12.1.4.2, and 11.5.2-11.6.4, BIG-IQ 6.0.0-6.1.0 and 5.1.0-5.4.0, iWorkflow 2.3.0, and Enterprise Manager 3.1.1, authenticated users with the ability to upload files (via scp, for example) can escalate their privileges to allow root shell access from within the TMOS Shell (tmsh) interface. The tmsh interface allows users to execute a secondary program via tools like sftp or scp. |
| On BIG-IP 11.5.1-11.6.4, iRules performing HTTP header manipulation may cause an interruption to service when processing traffic handled by a Virtual Server with an associated HTTP profile, in specific circumstances, when the requests do not strictly conform to RFCs. |
| On BIG-IP 14.1.0-14.1.0.5, undisclosed SSL traffic to a virtual server configured with a Client SSL profile may cause TMM to fail and restart. The Client SSL profile must have session tickets enabled and use DHE cipher suites to be affected. This only impacts the data plane, there is no impact to the control plane. |
| On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.4, 13.0.0-13.1.1.4, and 12.1.0-12.1.4, undisclosed traffic sent to BIG-IP iSession virtual server may cause the Traffic Management Microkernel (TMM) to restart, resulting in a Denial-of-Service (DoS). |
| On BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, and 12.1.0-12.1.4, the Traffic Management Microkernel (TMM) may restart when a virtual server has an HTTP/2 profile with Application Layer Protocol Negotiation (ALPN) enabled and it processes traffic where the ALPN extension size is zero. |
| On BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8, administrative users with TMSH access can overwrite critical system files on BIG-IP which can result in bypass of whitelist / blacklist restrictions enforced by appliance mode. |
| On BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8, DNS query TCP connections that are aborted before receiving a response from a DNS cache may cause TMM to restart. |
| When BIG-IP 14.0.0-14.1.0.1, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8 are processing certain rare data sequences occurring in PPTP VPN traffic, the BIG-IP system may execute incorrect logic. The TMM may restart and produce a core file as a result of this condition. The BIG-IP system provisioned with the CGNAT module and configured with a virtual server using a PPTP profile is exposed to this vulnerability. |
| A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). The integrated webserver does not invalidate the Session ID upon user logout. An attacker that successfully extracted a valid Session ID is able to use it even after the user logs out. The security vulnerability could be exploited by an attacker in a privileged network position who is able to read the communication between the affected device and the user or by an attacker who is able to obtain valid Session IDs through other means. The user must invoke a session to the affected device. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28). A denial of service vulnerability exists in the affected products. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. |
| A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. |