| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An Integer Underflow in MP4_EIA608_Convert() in modules/demux/mp4/mp4.c in VideoLAN VLC media player through 3.0.7.1 allows remote attackers to cause a denial of service (heap-based buffer overflow and crash) or possibly have unspecified other impact via a crafted .mp4 file. |
| The Zoom Client before 4.4.53932.0709 on macOS allows remote code execution, a different vulnerability than CVE-2019-13450. If the ZoomOpener daemon (aka the hidden web server) is running, but the Zoom Client is not installed or can't be opened, an attacker can remotely execute code with a maliciously crafted launch URL. NOTE: ZoomOpener is removed by the Apple Malware Removal Tool (MRT) if this tool is enabled and has the 2019-07-10 MRTConfigData. |
| An issue was discovered in OpenLDAP 2.x before 2.4.48. When using SASL authentication and session encryption, and relying on the SASL security layers in slapd access controls, it is possible to obtain access that would otherwise be denied via a simple bind for any identity covered in those ACLs. After the first SASL bind is completed, the sasl_ssf value is retained for all new non-SASL connections. Depending on the ACL configuration, this can affect different types of operations (searches, modifications, etc.). In other words, a successful authorization step completed by one user affects the authorization requirement for a different user. |
| D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console. |
| GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment. |
| In WebAccess versions 8.4.1 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. |
| GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service. |
| In WebAccess versions 8.4.1 and prior, multiple command injection vulnerabilities are caused by a lack of proper validation of user-supplied data and may allow arbitrary file deletion and remote code execution. |
| Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication. |
| In Horner Automation Cscape 9.90 and prior, improper validation of data may cause the system to write outside the intended buffer area, which may allow arbitrary code execution. |
| Delta Electronics TPEditor, Versions 1.94 and prior. Multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files, which may allow remote code execution. |
| In Horner Automation Cscape 9.90 and prior, an improper input validation vulnerability has been identified that may be exploited by processing files lacking user input validation. This may allow an attacker to access information and remotely execute arbitrary code. |
| Delta Electronics TPEditor, Versions 1.94 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code. |
| 3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only. |
| The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash. |
| Delta Electronics TPEditor, Versions 1.94 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code. |
| Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code. |
| In Omron PLC CJ series, all versions, and Omron PLC CS series, all versions, an attacker could monitor traffic between the PLC and the controller and replay requests that could result in the opening and closing of industrial valves. |
| CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. |
| Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware. |