| An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability [CWE-79] vulnerability in Fortinet FortiSandbox 5.0.0 through 5.0.2, FortiSandbox 4.4.0 through 4.4.7, FortiSandbox 4.2 all versions, FortiSandbox 4.0 all versions may allow an authenticated privileged attacker to execute code via crafted requests. |
| A cleartext storage of sensitive information vulnerability [CWE-312] vulnerability in Fortinet FortiMail 7.6.0 through 7.6.2, FortiMail 7.4.0 through 7.4.4, FortiMail 7.2.0 through 7.2.7, FortiMail 7.0.0 through 7.0.8, FortiRecorder 7.2.0 through 7.2.3, FortiRecorder 7.0 all versions, FortiRecorder 6.4 all versions, FortiVoice 7.2.0, FortiVoice 7.0.0 through 7.0.6 may allow an authenticated malicious administrator to obtain user's secrets via CLI commands. Practical exploitability is limited by conditions out of the control of the attacker: An admin must log in to the targeted device. |
| A deserialization vulnerability in LimeSurvey before v6.15.0+250623 allows a remote attacker to execute arbitrary code on the server. |
| A improper certificate validation vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.4, FortiAnalyzer 7.4.0 through 7.4.8, FortiAnalyzer 7.2 all versions, FortiAnalyzer 7.0 all versions, FortiAnalyzer 6.4 all versions, FortiManager 7.6.0 through 7.6.4, FortiManager 7.4.0 through 7.4.8, FortiManager 7.2 all versions, FortiManager 7.0 all versions, FortiManager 6.4 all versions may allow a remote unauthenticated attacker to view confidential information via a man in the middle [MiTM] attack. |
| A use of externally-controlled format string vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.4, FortiAnalyzer 7.4.0 through 7.4.7, FortiAnalyzer 7.2 all versions, FortiAnalyzer 7.0 all versions, FortiAnalyzer Cloud 7.6.0 through 7.6.4, FortiAnalyzer Cloud 7.4.0 through 7.4.7, FortiAnalyzer Cloud 7.2 all versions, FortiAnalyzer Cloud 7.0 all versions, FortiManager 7.6.0 through 7.6.4, FortiManager 7.4.0 through 7.4.7, FortiManager 7.2 all versions, FortiManager 7.0 all versions, FortiManager Cloud 7.6.0 through 7.6.4, FortiManager Cloud 7.4.0 through 7.4.7, FortiManager Cloud 7.2 all versions, FortiManager Cloud 7.0 all versions may allow an attacker to escalate its privileges via specially crafted requests. |
| GNU Binutils thru 2.45.1 readelf contains a denial-of-service vulnerability when processing a crafted binary with malformed DWARF loclists data. A logic flaw in the DWARF parsing code can cause readelf to repeatedly print the same table output without making forward progress, resulting in an unbounded output loop that never terminates unless externally interrupted. A local attacker can trigger this behavior by supplying a malicious input file, causing excessive CPU and I/O usage and preventing readelf from completing its analysis. |
| CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload. |
| SQL Injection vulnerability in LimeSurvey before v.6.15.4+250710 allows a remote attacker to obtain sensitive information from the database. |
| In the Linux kernel, the following vulnerability has been resolved:
fs/xattr: missing fdput() in fremovexattr error path
In the Linux kernel, the fremovexattr() syscall calls fdget() to acquire a
file reference but returns early without calling fdput() when
strncpy_from_user() fails on the name argument. In multi-threaded processes
where fdget() takes the slow path, this permanently leaks one
file reference per call, pinning the struct file and associated kernel
objects in memory. An unprivileged local user can exploit this to cause
kernel memory exhaustion. The issue was inadvertently fixed by commit
a71874379ec8 ("xattr: switch to CLASS(fd)"). |
| CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels. |
| CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default. |
| A command injection vulnerability was identified in the web module of Archer AXE75 v1.6/v1.0 router. An authenticated attacker with adjacent-network access may be able to perform remote code execution (RCE) when the router is configured with sysmode=ap. Successful exploitation results in root-level privileges and impacts confidentiality, integrity and availability of the device.
This issue affects Archer AXE75 v1.6/v1.0: through 1.3.2 Build 20250107. |
| A security vulnerability has been detected in open-webui up to 0.6.16. Affected is an unknown function of the file backend/start_windows.bat of the component JWT Key Handler. Such manipulation of the argument WEBUI_SECRET_KEY leads to insufficiently random values. It is possible to launch the attack remotely. The attack requires a high level of complexity. The exploitability is told to be difficult. The exploit has been disclosed publicly and may be used. |
| Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, M700V Series M750VW, M720VW, 730VW, M720VS, M730VS, and M750VS, M70V Series M70V, E70 Series E70, and Software Tools NC Trainer2 and NC Trainer2 plus allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition by sending specially crafted packets to TCP port 683. |
| A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable. |
| IBM Planning Analytics Advanced Certified Containers 3.1.0 through 3.1.4 could allow a local privileged user to obtain sensitive information from environment variables. |
| Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through social engineering a legitimate user to import a specially crafted trace file |
| An unauthenticated remote attacker may use hardcodes credentials to get access to the previously activated FTP Server with limited read and write privileges. |
| An unauthenticated remote attacker can use firmware images to extract password hashes and brute force plaintext passwords of accounts with limited access. |
| An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server. |