| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered on Humax Digital HG100R 2.0.6 devices. To download the backup file it's not necessary to use credentials, and the router credentials are stored in plaintext inside the backup, aka GatewaySettings.bin. |
| An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access. |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. |
| IBM Security Identity Manager Adapters 6.0 and 7.0 does not perform an authentication check for a critical resource or functionality allowing anonymous users access to protected areas. IBM X-Force ID: 128621. |
| Aodh as packaged in Openstack Ocata and Newton before change-ID I8fd11a7f9fe3c0ea5f9843a89686ac06713b7851 and before Pike-rc1 does not verify that trust IDs belong to the user when creating alarm action with the scheme trust+http, which allows remote authenticated users with knowledge of trust IDs where Aodh is the trustee to obtain a Keystone token and perform unspecified authenticated actions by adding an alarm action with the scheme trust+http, and providing a trust id where Aodh is the trustee. |
| Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command. |
| In Odoo 8.0, Odoo Community Edition 9.0 and 10.0, and Odoo Enterprise Edition 9.0 and 10.0, remote attackers can bypass authentication under certain circumstances because parameters containing 0x00 characters are truncated before reaching the database layer. This occurs because Psycopg 2.x before 2.6.3 is used. |
| The 'Find Phone' function in Nice smartphones with software versions earlier before Nice-AL00C00B0135 has an authentication bypass vulnerability. An unauthenticated attacker may wipe and factory reset the phone by special steps. Due to missing authentication of the 'Find Phone' function, an attacker may exploit the vulnerability to bypass the 'Find Phone' function in order to use the phone normally. |
| ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict access to the factory reset page. An unauthenticated, remote attacker can exploit this vulnerability by directly accessing the http://x.x.x.x/setup/setup_maintain_firmware-default.html page. This will allow an attacker to perform a factory reset on the device, leading to a denial of service condition or the ability to make use of default credentials (CVE-2017-3186). |
| WiMAX routers based on the MediaTek SDK (libmtk) that use a custom httpd plugin are vulnerable to an authentication bypass allowing a remote, unauthenticated attacker to gain administrator access to the device by performing an administrator password change on the device via a crafted POST request. |
| Sony PCS-XG100, PCS-XG100S, PCS-XG100C, PCS-XG77, PCS-XG77S, PCS-XG77C devices with firmware versions prior to Ver.1.51 and PCS-XC1 devices with firmware version prior to Ver.1.22 allow an attacker on the same network segment to bypass authentication to perform administrative operations via unspecified vectors. |
| OSRAM SYLVANIA Osram Lightify Home before 2016-07-26 allows remote attackers to execute arbitrary commands via TCP port 4000. |
| With X-Pack installed, Kibana versions 5.0.0 and 5.0.1 were not properly authenticating requests to advanced settings and the short URL service, any authenticated user could make requests to those services regardless of their own permissions. |
| A privilege escalation vulnerability in the Secure Shell (SSH) subsystem in the StarOS operating system for Cisco ASR 5000 Series, ASR 5500 Series, ASR 5700 Series devices, and Cisco Virtualized Packet Core could allow an authenticated, remote attacker to gain unrestricted, root shell access. The vulnerability is due to missing input validation of parameters passed during SSH or SFTP login. An attacker could exploit this vulnerability by providing crafted user input to the SSH or SFTP command-line interface (CLI) during SSH or SFTP login. An exploit could allow an authenticated attacker to gain root privileges access on the router. Note: Only traffic directed to the affected system can be used to exploit this vulnerability. This vulnerability can be triggered via both IPv4 and IPv6 traffic. An established TCP connection toward port 22, the SSH default port, is needed to perform the attack. The attacker must have valid credentials to login to the system via SSH or SFTP. The following products have been confirmed to be vulnerable: Cisco ASR 5000/5500/5700 Series devices running StarOS after 17.7.0 and prior to 18.7.4, 19.5, and 20.2.3 with SSH configured are vulnerable. Cisco Virtualized Packet Core - Single Instance (VPC-SI) and Distributed Instance (VPC-DI) devices running StarOS prior to N4.2.7 (19.3.v7) and N4.7 (20.2.v0) with SSH configured are vulnerable. Cisco Bug IDs: CSCva65853. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration. |
| The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit. |
| The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit. |
| An issue was discovered in Logpoint before 7.5.0. An endpoint used by Distributed Logpoint Setup was exposed, allowing unauthenticated attackers to bypass CSRF protections and authentication. |
| Aethon TUG Home Base Server versions prior to version 24 are affected by un unauthenticated attacker who can freely access hashed user credentials. |
| A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition. |