Search Results (20302 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-2900 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2901 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 8.8 High
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2902 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 8.8 High
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2891 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2581 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-22 8.8 High
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.
CVE-2024-2903 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 8.8 High
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-6749 1 Zephyrproject 1 Zephyr 2025-01-22 8 High
Unchecked length coming from user input in settings shell
CVE-2024-31496 1 Fortinet 3 Fortianalyzer, Fortianalyzer Big Data, Fortimanager 2025-01-21 6.3 Medium
A stack-based buffer overflow vulnerability [CWE-121] in Fortinet FortiManager version 7.4.0 through 7.4.2 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.2 and before 7.2.5 and FortiAnalyzer-BigData 7.4.0 and before 7.2.7 allows a privileged attacker to execute unauthorized code or commands via crafted CLI requests.
CVE-2024-8748 1 Zyxel 127 Ax7501-b0, Ax7501-b0 Firmware, Ax7501-b1 and 124 more 2025-01-21 7.5 High
A buffer overflow vulnerability in the packet parser of the third-party library "libclinkc" in Zyxel VMG8825-T50K firmware versions through V5.50(ABOM.8.4)C0 could allow an attacker to cause a temporary denial of service (DoS) condition against the web management interface by sending a crafted HTTP POST request to a vulnerable device.
CVE-2024-9197 1 Zyxel 72 Ax7501-b0, Ax7501-b0 Firmware, Ax7501-b1 and 69 more 2025-01-21 4.9 Medium
A post-authentication buffer overflow vulnerability in the parameter "action" of the CGI program in Zyxel VMG3625-T50B firmware versions through V5.50(ABPM.9.2)C0 could allow an authenticated attacker with administrator privileges to cause a temporary denial of service (DoS) condition against the web management interface by sending a crafted HTTP GET request to a vulnerable device if the function ZyEE is enabled.
CVE-2020-12819 1 Fortinet 1 Fortios 2025-01-21 5.4 Medium
A heap-based buffer overflow vulnerability in the processing of Link Control Protocol messages in FortiGate versions 5.6.12, 6.0.10, 6.2.4 and 6.4.1 and earlier may allow a remote attacker with valid SSL VPN credentials to crash the SSL VPN daemon by sending a large LCP packet, when tunnel mode is enabled. Arbitrary code execution may be theoretically possible, albeit practically very difficult to achieve in this context
CVE-2020-12820 1 Fortinet 1 Fortios 2025-01-21 5.4 Medium
Under non-default configuration, a stack-based buffer overflow in FortiOS version 6.0.10 and below, version 5.6.12 and below may allow a remote attacker authenticated to the SSL VPN to crash the FortiClient NAC daemon (fcnacd) and potentially execute arbitrary code via requesting a large FortiClient file name. We are not aware of proof of concept code successfully achieving the latter.
CVE-2024-4064 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-21 8.8 High
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4065 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-21 8.8 High
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4066 1 Tenda 2 Ac8, Ac8 Firmware 2025-01-21 8.8 High
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3905 1 Tenda 2 Ac500, Ac500 Firmware 2025-01-21 8.8 High
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3906 1 Tenda 2 Ac500, Ac500 Firmware 2025-01-21 8.8 High
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3910 1 Tenda 2 Ac500, Ac500 Firmware 2025-01-21 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3875 1 Tenda 2 F1202, F1202 Firmware 2025-01-21 8.8 High
A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3876 1 Tenda 2 F1202, F1202 Firmware 2025-01-21 8.8 High
A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.