Search Results (44049 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-2140 1 Smartics 1 Smartics 2025-04-16 8.8 High
Elcomplus SmartICS v2.3.4.0 does not neutralize user-controllable input, which allows an authenticated user to inject arbitrary code into specific parameters.
CVE-2022-2199 1 Micodus 2 Mv720, Mv720 Firmware 2025-04-16 7.5 High
The main MiCODUS MV720 GPS tracker web server has a reflected cross-site scripting vulnerability that could allow an attacker to gain control by tricking a user into making a request.
CVE-2022-40965 1 Deltaww 1 Diaenergie 2025-04-16 8.7 High
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API.
CVE-2022-41555 1 Deltaww 1 Diaenergie 2025-04-16 8.7 High
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting API.
CVE-2022-41701 1 Deltaww 1 Diaenergie 2025-04-16 8.7 High
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API.
CVE-2022-41651 1 Deltaww 1 Diaenergie 2025-04-16 8.7 High
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API.
CVE-2022-41702 1 Deltaww 1 Diaenergie 2025-04-16 8.7 High
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API.
CVE-2022-40190 1 Sauter-controls 1 Moduweb Firmware 2025-04-16 8.8 High
SAUTER Controls moduWeb firmware version 2.7.1 is vulnerable to reflective cross-site scripting (XSS). The web application does not adequately sanitize request strings of malicious JavaScript. An attacker utilizing XSS could then execute malicious code in users’ browsers and steal sensitive information, including user credentials.
CVE-2024-22083 1 Elspec-ltd 2 G5dfr, G5dfr Firmware 2025-04-16 6.5 Medium
An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks.
CVE-2021-23233 1 Fresenius-kabi 8 Agilia Connect, Agilia Connect Firmware, Agilia Partner Maintenance Software and 5 more 2025-04-16 7.3 High
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
CVE-2021-44464 1 Fresenius-kabi 8 Agilia Connect, Agilia Connect Firmware, Agilia Partner Maintenance Software and 5 more 2025-04-16 6.3 Medium
Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software.
CVE-2021-33848 1 Fresenius-kabi 8 Agilia Connect, Agilia Connect Firmware, Agilia Partner Maintenance Software and 5 more 2025-04-16 5.4 Medium
Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 is vulnerable to reflected cross-site scripting attacks. An attacker could inject JavaScript in a GET parameter of HTTP requests and perform unauthorized actions such as stealing internal information and performing actions in context of an authenticated user.
CVE-2022-22987 1 Advantech 2 Adam-3600, Adam-3600 Firmware 2025-04-16 9.8 Critical
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.
CVE-2022-21146 1 Ipcomm 2 Ipdio, Ipdio Firmware 2025-04-16 6.3 Medium
Persistent cross-site scripting in the web interface of ipDIO allows an unauthenticated remote attacker to introduce arbitrary JavaScript by injecting an XSS payload into a specific parameter. The XSS payload will be executed when a legitimate user attempts to review history.
CVE-2022-24432 1 Ipcomm 2 Ipdio, Ipdio Firmware 2025-04-16 5.5 Medium
Persistent cross-site scripting (XSS) in the web interface of ipDIO allows an authenticated remote attacker to introduce arbitrary JavaScript by injecting an XSS payload into specific fields. The XSS payload will be executed when a legitimate user attempts to upload, copy, download, or delete an existing configuration (Administrative Services).
CVE-2021-27416 1 Hitachienergy 1 Ellipse Enterprise Asset Management 2025-04-16 5.5 Medium
An attacker could exploit this vulnerability in Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 by tricking a user to click on a link containing malicious code that would then be run by the web browser. This can result in the compromise of confidential information, or even the takeover of the user’s session.
CVE-2022-25246 1 Ptc 2 Axeda Agent, Axeda Desktop Server 2025-04-16 9.8 Critical
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.
CVE-2020-25180 3 Rockwellautomation, Schneider-electric, Xylem 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more 2025-04-16 5.3 Medium
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
CVE-2020-25193 1 Ge 6 Rt430, Rt430 Firmware, Rt431 and 3 more 2025-04-16 5.3 Medium
By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection.
CVE-2021-27418 1 Ge 38 Multilin B30, Multilin B30 Firmware, Multilin B90 and 35 more 2025-04-16 5.3 Medium
GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings.