| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| [PROBLEMTYPE] in [COMPONENT] in [VENDOR] [PRODUCT] [VERSION] on [PLATFORMS] allows [ATTACKER] to [IMPACT] via [VECTOR] |
| A deserialization vulnerability in LimeSurvey before v6.15.0+250623 allows a remote attacker to execute arbitrary code on the server. |
| CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload. |
| SQL Injection vulnerability in LimeSurvey before v.6.15.4+250710 allows a remote attacker to obtain sensitive information from the database. |
| CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels. |
| CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default. |
| A security vulnerability has been detected in open-webui up to 0.6.16. Affected is an unknown function of the file backend/start_windows.bat of the component JWT Key Handler. Such manipulation of the argument WEBUI_SECRET_KEY leads to insufficiently random values. It is possible to launch the attack remotely. The attack requires a high level of complexity. The exploitability is told to be difficult. The exploit has been disclosed publicly and may be used. |
| Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, M700V Series M750VW, M720VW, 730VW, M720VS, M730VS, and M750VS, M70V Series M70V, E70 Series E70, and Software Tools NC Trainer2 and NC Trainer2 plus allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition by sending specially crafted packets to TCP port 683. |
| A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable. |
| IBM Planning Analytics Advanced Certified Containers 3.1.0 through 3.1.4 could allow a local privileged user to obtain sensitive information from environment variables. |
| An unauthenticated remote attacker may use hardcodes credentials to get access to the previously activated FTP Server with limited read and write privileges. |
| An unauthenticated remote attacker can use firmware images to extract password hashes and brute force plaintext passwords of accounts with limited access. |
| An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server. |
| An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability [CWE-22] vulnerability in Fortinet FortiSOAR Agent Communication Bridge 1.1.0, FortiSOAR Agent Communication Bridge 1.0 all versions may allow an unauthenticated attacker to read files accessible to the fortisoar user on a system where the agent is deployed, via sending a crafted request to the agent port. |
| Incorrect Access Control via activation token reuse on the password-reset endpoint allowing unauthorized password resets and full account takeover. Affected Product: Deutsche Telekom AG Telekom Account Management Portal, versions before 2025-10-27, fixed 2025-10-31. |
| Incorrect Access Control via missing 2FA rate-limiting allowing unlimited brute-force retries and full MFA bypass with no user interaction required. Affected Product: Deutsche Telekom AG Telekom Account Management Portal, versions before 2025-10-24, fixed 2025-11-03. |
| An issue pertaining to CWE-79: Improper Neutralization of Input During Web Page Generation was discovered in benkeen generatedata 4.0.14. |
| An issue pertaining to CWE-79: Improper Neutralization of Input During Web Page Generation was discovered in Sunbird-Ed SunbirdEd-portal v1.13.4. |
| The MetForm Pro plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the Quiz feature in all versions up to, and including, 3.9.6 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. |
| CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file. |